Evolution 350 UV-Vis Spectrophotometer
Model: Evolution 350 UV-VIS
Thermo - USA
The Thermo Scientific™ Evolution™350 UV-Visible (UV-Vis) Spectrophotometer is designed to meet the challenges and requirements of pharmaceutical, industrial QA/QC, chemical, environmental, materials science, academic, life science, and food and beverage laboratories.
Fully Automated Tablet Dissolution Testing System
Model: ADS-L 820
Pharmatest - Germany
The online dissolution system ADS-L 820 consists of a Pharma Test dissolution tester PTWS 820D, the DAD UV/VIS spectrophotometer TIDAS® L and a multi-channel pump. The system is controlled by the 21 CFR Part 11 compliant user friendly WinDiss ARGUS dissolution software
PTWS 1220 6+6 USP/EP Tablet Dissolution Testing Instrument
Model: PTWS 1220
Pharmatest - Germany
The PTWS 1220 is a 6+6 position, single drive tablet dissolution testing instrument for solid dosage forms as described in USP chapter <711/724> and EP section<2.9.3/4> as well as the DAB/BP and Japanese Pharmacopeia section <15>.
PT-DT70 Low-Head Tablet Dissolution
Model: PT-DT70
Pharmatest - Germany
The PT-DT70 is the low head flip back dissolution testing instrument from Pharma Test. It provides a spacen saving, low cost entry into dissolution testing. Whether for a new laboratory or to meet tough budget requirements, the PT-DT70 offers a lot of instrument for a comparatively modest cost. The ideal instrument for all USP <711/724> and EP <2.9.3/4> applications for which automated and manual operation is required
PTWS 120D 6-Station Tablet Dissolution
Model: PTWS 120D
Pharmatest - Germany
The PTWS 120D is an 6 position, single drive compact tablet dissolution testing instrument for solid dosage forms as described in USP chapter <711/724> and EP section<2.9.3/4> as well as the DAB and Japanese Pharmacopeia section <15>.
PTWS 820D USP/EP Tablet Dissolution
Model: PTWS 820D
Pharmatest - Germany
The PTWS 820D is an 8 position, single drive compact tablet dissolution testing instrument for solid dosage forms as described in USP chapter <711/724> and EP section <2.9.3/4> as well as the DAB and Japanese Pharmacopeia section <15>
PTS-3E Suppository Disintegration
Model: PTS-3E
Pharmatest - Germany
The PTS-3E Suppository and Pessaries Disintegration Tester is designed and manufactured in compliance to the EP monograph <2.9.2.1/2.9.2.2> and the German DAB Pharmacopoeia.
PTZ-S Single Basket Tablet Disintegration
Model: PTZ S
Pharmatest - Germany
The PTZ-S is a manual tablet disintegration testing instrument, manufactured according to the recent USP <701/2040>, EP <2.9.1/2.9.1.2>, JP and other pharmacopoeias.
DIST-3 Triple Basket Tablet Disintegration
Model: DIST 3
Pharmatest - Germany
The DIST-3 is a three-basket manual tablet disintegration testing instrument, manufactured according to the recent USP <701/2040>, EP <2.9.1/2.9.1.2>, JP and other pharmacopoeias.
PTZ AUTO Semi-Automated Tablet Disintegration
Model: PTZ AUTO Semi
Pharmatest - Germanay
The PTZ AUTO disintegration test instruments are available as single, double, triple and four station systems. They are equipped in full compliance with the current USP <701/2040> and EP <2.9.1/2.9.2.1> Pharmacopoeia
PTZ AUTO EZ Fully Automated Tablet Disintegration
Model: PTZ AUTO EZ
Pharmatest - Germany
The fully automated PTZ AUTO EZ instruments are available as 1, 2, 3 or 4 station models. The instruments are capable to automatically detect the individual disintegration times of tablets and other solid dosage forms. Each automated disintegration basket can be operated independently. They are equipped in full compliance with the USP<701/2040> and EP<2.9.1/2.9.1.2> pharmacopoeia requirements.
PTB 302 / PTB 502 Manual Tablet Hardness
Model: PTB 302 / PTB 502
Pharmatest - Germany
The digital tablet hardness testing instrument PTB 302 features an integrated report printer. It is a single force mode hardness test apparatus adjusted for linear force increase while tablet hardness is tested. It offers a multiple point validation procedure for the built-in digital load cell. The instrument is made in strict compliance with the EP <2.9.8> and USP <1217> Pharmacopoeia.
PTB 111E Manual Tablet Hardness
Model: PTB 111E
Pharmatest - Germany
The manual tablet hardness testing instrument PTB111E / 111E-500 / 111E-800 is a dual force mode hardness test apparatus as it can be used for either linear force or linear speed increase while tablet hardness is tested. It offers a multiple point validation procedure for the built-in digital load cell. The instrument is made in strict compliance with the EP <2.9.8> and USP <1217> Pharmacopoeia.
WHT 3 ME Fully Automated 4 in 1 Tablet
Model: WHT 3ME
Pharmatest - Germany
Test weight, thickness (or height), diameter (or length), and hardness of regular tablets, odd shaped tablets (caplets, oblongs etc.) and other solid samples fully automatically. Use the WHT 3ME for the fully automated testing of single tablet critical parameters including weight (in compliance to the European and German Pharmacopoeia for uniformity of mass), thickness, diameter and the tablet hardness also according to the European EP <2.9.8> and USP <1217> Pharmacopoeia.
PTF-20E-and-PTF-20ER-Tablet-Friability-Test-Instrument
Model: PTF-20E-and-PTF-20ER
Pharmatest - Germany
The PTF 20E and PTF 20ER are double-drum instruments, fixed or variable speed tablet friability test Instruments are manufactured in compliance to the USP <1216>, EP <2.9.7> and other Pharmacopoeias
MiniPress II Fully Automated Rotary Tablet Press
Model: MiniPress II
Pharmag - Germany
The MiniPress II Fully Automated Rotary Tablet Press is a robust versatile machine, which is designed to meet the strict GMP requirements. It is an ideal solution for R&D, small batch production and above all for Galenic Formulation Development, feasibility studies and for Preparation of Master Manufacturing Procedures.
RIVA MiniPress Single Punch Tablet Press
Model: RIVA MiniPress
Pharmag - Germany
The RIVA MiniPress is a single punch, off-center, tablet press. It is ideal for the production of small batches as well as for Pharmaceutical Research & Development. It is designed under strict GMP regulations.
Powder Testing
Model : PTG S4
Pharmatest - Germany
Powders are used in many industries today and the bulk properties of a powder are dependent upon the preparation, treatment, and storage of a sample. Since small disturbances of bulk powders result in a changed bulk density, it is often very diffcult to measure with good reproducibility. The Pharma Test powder testing product portfolio includes instruments to not only measure bulk density but also tap density and flowability. We also offer added benefts by combining flowability measurement with NIR (near-infrared) spectroscopy to give as much in-depth information about your powders as possible.